Wednesday 13. November 2019
Sitemap
Powel Descaler - electronic water conditioner - logo
  Home Presentation
   Introduction       How it works       Products       Buy       Installation       Download       Dealers Application       Distributors       Contact   
DESCALER HE 15
DESCALER HE 25
DESCALER HE 50
DESCALER Pro Series
Recommendation for
   installation

DESCALER Pro Series

INSTALLATION INSTRUCTIONS

INSTALLATION
The installation consists of wrapping 2 field coils next to each other around the water-supply pipe, fixing the box onto the wall and connecting the coil and the box.

Installation of the coil:
Wrap 2 coils each 30 times (see fig.1) around the horizontal or vertical pipe while the distance between the ends of the coils and the bends, valves, joints, heater or boiler inlet etc. must be minimum three times the outer diameter of the pipe in order to avoid unwanted water turbulence in the place where the coils are wounded. The direction of the winding is not important. Tightly fix the ends of both coils with plastic bands. The length of the loose ends of the wire should be approximately of the same length.


DESCALER limestone protection unit



Installation of the box:
Screw the plastic clips into the rear panel of the box. The box construction allows the horizontal as well as vertical position of the clips. Put the box on the wall and mark the holes in the clips with a sharp tipped object or a pencil. Drill the holes (depth about 35 mm, drill diameter 6 mm) and put

PUTTING INTO OPERATION
Plug the connectors into the outlets of the unit. The wire leads should not be too tight and they must not be entwined together.
The unit is powered by 12 V= direct regulated current from the mains adapter. Connect the power supply to the unit and plug the adapter into an electrical socket. The green LED (POWER) indicates the proper functioning.
The red LED is blinking, and at the same time a discontinuous acoustic sound can be heard, after the coil circuit was interrupted, for example, after unplugging the connector or if there is no signal in the output connectors (failure).
It is necessary to place the mains adapter in the environment where there is no threat of spattering water. In case there is the possibility of spattering water, it is necessary to place the mains adapter into the case IP 54.

All prices include
tax and shipping
e-shop




About your water: Hard water | Water hardness | Limescale | Water treatment | Electronic Water Conditioner | Water Conditioner | Water Softener |
webdesign by Shuster & Ori
Copyright ©1999 - 2005. All rights reserved