DESCALER HE 25 INSTALLATION

INSTRUCTIONS

INSTALLATION:
As the picture shows the installation of DESCALER HE25 is very simple and does not require any plumbing or fitting works. The installation consists of wrapping the field coil around the water-supply pipe, fixing the box onto the wall and connecting the coil and the box.

Installation of the coil:
Wrap the coil 11 times around the horizontal or vertical pipe while the distance between the ends of the coil and the bends, valves, joints, boilers or heaters inlet etc. must be minimum three times the outer diameter of the pipe in order to avoid unwanted water turbulence in the place where the coil is wound. The direction of the winding is not important. Tightly fix the ends of the coil with plastic bands.
If practicable, the coil wire leads can be shortened to the lengths of 20 cm the following way: Unscrew the plastic cover of the banana pin, loosen the worm and pull out the wire. Shorten the wire to the required length, remove the insulation at its end (about 7 mm), insert the wire back into the banana pin and tighten the worm. Finally, screw the plastic cover onto the banana pin. Do not twist the wires. In case of very hard water (over 300 ppm) we recommend installation of the coil on plastic pipe or winding two coils - 11 turns each (fig. 2) for steel pipe (distance between the coils - 15 cm).




Installation of the box:
Use the drilling jig and a sharp tipped object to mark holes not far from the coil. Then drill the holes of the diameter of 6 mm. Put wall plugs into the holes and drive in screws so that their heads jut out over the wall by about 5 mm. There are openings on the rear cover of the electronic unit; put the box on the wall the way that the screw heads get through the openings and slide the box downwards.

PUTTING INTO OPERATION
Plug the connectors into the outlets of the unit. The wire leads should not be too tight and they must not be entwined together.
The unit is powered by 12 V= direct regulated current from the power adapter. Connect the power supply to the unit and plug the adapter into an electrical socket. The green LED (POWER) indicates the proper functioning. The red LED (ERROR) is blinking, and at the same time a discontinuous acoustic sound can be heard, after the coil circuit was interrupted, for example, after unplugging the connector or if there is no signal in the output connectors (failure). It is necessary to place the adapter in the environment where there is no threat of spattering water. In case there is the possibility of spattering water, it is necessary to place the adapter into the case IP 54.